Deutz 1012 Dokumentacja Strona 117

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 282
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 116
Service Training
Page 4.2
Section 59
09.04
Install LP gauge with adapter V to port F of power limiter. Start engine and read
pressure gauge.
Fully depress brake pedal with engine running and observe pressure gauge.
Pressure drops to
approx. 0 bar.
Way valve (46) (brake shaft)
setting incorrect. Put in order or
renew travel control unit.
Remove adapter IV. Reconnect external brake release port R and close the
grummet. Start engine, release brake and fully depress F and R accelerator
pedals.
Disc brake of rotating wheel
not functioning correctly.
Remove and eliminate fault
Braking system okay.Traction wheels rotating.
yes no
yes no
yes no
yes no
Check "Hydrostatic travel
drive".
A
Install LP gauge with adapter IV to external release port R. Start engine and
read pressure with the brake released.
Minimum pressure
17.5 bar obtained.
Minimum pressure
17.5 bar obtained.