Page 30
Section 4.1
Service Training
09.06
4.1.2.6 THERMOSTAT
REMOVAL
- Drain coolant, collect it, and dispose of it in accordance
with legal standards.
- Dismantle outlet connecting piece. Remove thermostat.
NOTE: Collect coolant and dispose of it in
accordance with legal standards.
- Attach new sealing ring to thermostat. Insert thermostat
together with new sealing ring.
NOTE: Mind operating position of thermostat. Arrow
(venting notch) points to the top.
- Attach outlet connecting piece.
Required tightening torque: 30 Nm